Chapter 4

PC Utilities

4.3.2

Convert4 Command Line Switches

Convert4 supports several command-line switches to facilitate batch processing. To access its
Command Line Arguments window, open a command prompt window (select Accessories |
Command Prompt from the Start menu). Change directory (cd) to the directory on your hard drive that
Convert4 is stored. Type the following: convert4 -h

The Convert4 Command Line Arguments window appears as shown in Figure 12.

Table 5: NovAtel Logs for Rinex Conversion

NovAtel OEMV Family Log

Recommended Trigger

RANGEA/B, or

RANGECMPA/B

ontime 1

BESTPOSA/B, or

PSRPOSA/B, or

RTKPOSA/B, or

MARKPOSA/B

once

IONUTCA/B

onchanged

RAWEPHEMA/B

onchanged

GLORAWEPHEMA/B

onchanged

VERSIONA/B

a

a. Information from this log overrides data entered into the Receiver Number, Type and Version fields

using the OBS file button of the RINEX Headers section, see Figure 11 on Page 44.

once

SITEDEFA/B

b

b. Available on DL-V3 receivers, refer to the DL-V3 User Manual. Information from this log

overrides data entered into the Marker Name, Marker Number, Antenna Type and Antenna
Delta H fields using the OBS file button of the RINEX Headers section.