Smart-ag mating connectors, A.2.2 smart-ag connector and cable requirements – Novatel GNSS Receiver and Antenna SMART-AG User Manual

Page 63

Advertising
background image

SMART-AG User Manual Rev 5

63

A.2.2

SMART-AG Connector and Cable Requirements

Custom cables for installing your SMART-AG can be created using he following guidelines:

• Wire size: must be 0.5 mm-1.25 mm (20-16 AWG)
• Batt + connection must be protected by 5A fast blow fuse
• Serial data signals (TxD, RxD, signal ground) must be run in shielded cable.

Connect shields to ground at SMART-AG end only

• CAN signal conductors must be twisted (40 twists/m, 12 twists/ft)
• Use only the recommended mating connectors listed below. Use only gold plated

pins

The connector used in the SMART-AG is an “AMPSEAL” dust and water sealed type produced by
Tyco. The following part numbers pertain to the mating connector required to make connections to the
SMART-AG. These numbers are provided for information only and are not available from NovAtel as
separate parts.

Table 7: SMART-AG Mating Connectors

Table 8 details the part numbers for recommended fuses and fuse holders. These numbers are
provided for information only and are not available from NovAtel as separate parts.

Failure to observe the given cable construction guidelines in this section
will result in damage to the wiring (not covered by warranty).

Product

Part Description

Company

Part Number

SMART-AG mating connector

(Figure 28 on Page 61)

14-pin sealed receptacle

housing-black

Tyco/

AMP

776273-1

Gold plated pins for SMART-

AG connector/loose

Pins, loose piece

Tyco/

AMP

770854-3

Gold plated pins for SMART-

AG connector/strip

Pins, strip (reel)

Tyco/

AMP

770520-3

Seal Plug for unused pins on

mating connector

Seal Plug

Tyco/

AMP

770678-1