B.3 freset clear selected data from nvm and reset, Freset clear selected data from nvm and reset – Novatel GNSS Receiver and Antenna SMART-AG User Manual

Page 69

Advertising
background image

SMART-AG User Manual Rev 5

69

B.3 FRESET Clear Selected Data from NVM and Reset

The OEMV freset command is extended to include SMART-AG features. An additional target field,
userdata (value = 10), resets only the SMART-AG user data NVM, thereby resetting all parameters
indicated in this document as “Stored in NVM” to factory defaults. Issuing the freset command with
the “target” field set to standard, resets the userdata NVM as well as OEMV parameters as indicated
in the OEMV Family Firmware Reference Manual.

Issuing the FRESET command affects Tilt as follows:

Tilt sensor level is restored to the factory default

Tilt enable/disable will not be affected

If you issue the FRESET command without any parameters, it is the same as
issuing a FRESET STANDARD command.

Field

Field
Type

ASCII
Value

Binary

Value

Description

Binary

Format

Binary

Bytes

Binary

Offset

1

FRESET

header

-

-

This field contains the

command name or the

message header

depending on whether the

command is abbreviated

ASCII, ASCII or binary,

respectively.

-

H

0

2

target

See Table 13,

FRESET Target

on Page 70

Data to be reset by the

receiver

Enum

4

H

Advertising