Installing the shelf, Installing a multiplexer, Connecting an oadm – Nortel Networks 1000BASE-SX User Manual

Page 42

Advertising
background image

42

Optical multiplexers

Installing the shelf

The optical routing system (OADM/OMUX) is mounted in an optical shelf
with connections at the front of the module. For user access to these
connections, a minimum of 36 inches (90 cm) of clearance is required. Keep
the area as dust-free as possible.

Step

Action

1

Support the chassis so that all the mounting holes in the optical shelf
are aligned with the corresponding holes in the rack.

2

Attach two rack mounting bolts to each side of the rack.

3

Tighten all the bolts in rotation.

—End—

Installing a multiplexer

OADMs and OMUXs are passive devices that require no power for their
operation. You can inser them in the optical shelf and then connect them
into your network.

Step

Action

1

Align the plug-in module with the optical shelf.

2

Gently push the plug-in module into the shelf cavity.

3

Tighten the captive screws.

4

Connect the network cables.

—End—

Connecting an OADM

Use this procedure to connect the OADM to SFP or GBICs and to east and
west backbone interfaces.

Step

Action

1

Insert the GBIC or SFPs into their respective modules. Make sure
that you have the correct GBIC or SFP for your network configuration
by matching the color of the label to the color of the connector label
on the OADM.

2

Clean all fiber optica connectors on the cabling.

Nortel Metro Ethernet Routing Switch 8600

Installation — SFP, XFP, GBIC, and OADM Hardware Components

NN46220-301

01.01

Standard

5.0

1 May 2008

Copyright © 2008, Nortel Networks

.

Advertising
This manual is related to the following products: