Table 37 electrical power interface specifications – Nortel Networks 1000BASE-SX User Manual

Page 71

Advertising
background image

1000BASE-EX CWDM GBIC specifications

71

Parameter

Symbol

Minimum

Typical

Maximum

Receiver optical input power (BER <
10

-9

w/PRBS 2

7

-1) at 1.25 Gb/s, 60C

case temperature.

P

in

-30 dBm

-7 dBm

Receiver optical input power (BER <
10

-9

w/PRBS 2

7

-1) at 1.25 Gb/s, 70C

case temperature.

P

in

-28 dBm

-7 dBm

Dispersion power penalty at 60 km

2.0 dB

Dispersion power penalty at 100 km

3.0 dB

The following table describes the CWDM GBIC electrical power interface
specifications.

Table 37
Electrical power interface specifications

Parameter

Symbol

Minimum

Typical

Maximum

Supply current

I

s

250 mA

300 mA

Maximum voltage

V

max

6 V

Surge current

I

surge

350 mA

Input voltage

V

cc

4.75 V

5.00 V

5.25 V

Nortel Metro Ethernet Routing Switch 8600

Installation — SFP, XFP, GBIC, and OADM Hardware Components

NN46220-301

01.01

Standard

5.0

1 May 2008

Copyright © 2008, Nortel Networks

.