1000BASE-EX CWDM GBIC specifications

69

CAUTION

When shorter lengths of single mode fiber cable are used, there is
a risk of overloading the receiver. It may be necessary to insert
an in-line optical attenuator in the link to prevent overloading, as
follows:

Insert a 10 dB in-line optical attenuator between the
fiber optic cable plant and the receiving port on the
1000BASE-ZX GBIC, at each end of the link, if the fiber
optic cable span is less than 25 km.

Insert a 5 dB in-line optical attenuator between the
fiber optic cable plant and the receiving port on the
1000BASE-ZX GBIC, at each end of the link, if the fiber
optic cable span is less than 50 km.

The following table describes standards, connectors, cabling, and distance
for the 1000BASE-ZX GBIC.

Table 34
IEEE 802.3z 1000BASE-ZX GBIC specifications

Parameter

Specifications

Connectors

SC duplex

Cabling

SMF

Distance

Up to 70 km

Link optical power budget

22 dB

Transmitter characteristics

Wavelength

1550 ± 10 nm

Maximum spectral width

0.2 nm

Launch power

0 to 5.0 dBm

Receiver characteristics

Wavelength

1200 nm to 1620 nm

Receiver sensitivity

-22 dBm

Maximum input power

-3.0 dBm

1000BASE-EX CWDM GBIC specifications

This section provides technical specifications for the coarse wavelength
division multiplexing (CWDM) 1000BASE-EX GBIC models. The part
numbers of these GBICs range from AA1419017-E5 to AA1419024-E5.