Chapter 1

Getting Started

NI PXIe-1065 User Manual

1-14

ni.com

PXIe_SYNC_CTRL

PXIe_SYNC100 is by default a 10 ns pulse synchronous to PXI_CLK10.
The frequency of PXIe_SYNC100 is 10/n MHz, where n is a positive
integer. The default for n is 1, giving PXIe_SYNC100 a 100 ns period.
However, the backplane allows n to be programmed to other integers. For
instance, setting n = 3 gives a PXIe_SYNC100 with a 300ns period while
still maintaining its phase relationship to PXI_CLK10. The value for n may
be set to any positive integer from 1 to 255.

The system timing slot has a control pin for PXIe_SYNC100 called
PXIe_SYNC_CTRL for use when n > 1. Refer to Table B-7,

XP3

Connector Pinout for the System Timing Slot

, for system timing slot pinout.

Refer to Appendix A,

Specifications

, for the PXIe_SYNC_CTRL input

specifications.

By default, a high-level detected by the backplane on the
PXIe_SYNC_CTRL pin causes a synchronous restart for the
PXIe_SYNC100 signal. On the next PXI_CLK10 edge the
PXIe_SYNC100 signal will restart. This will allow several chassis to have
their PXIe_SYNC100 in phase with each other. Refer to Figure 1-7 for
timing details with this method.

Figure 1-7. PXIe_SYNC100 at 3.33 MHz Using PXIe_SYNC_CTRL as Restart

PXI_CLK10

PXIe_SYNC_CTRL

PXIe_SYNC100

SYNC100 Divider
Restarted Here