Chapter 1

Getting Started

NI PXIe-1065 User Manual

1-2

ni.com

If you are missing any of the items listed in Table 1-1, or if you have the
incorrect AC power cable, contact National Instruments.

Key Features

The NI PXIe-1065 chassis combines a high-performance 18-slot
PXI Express backplane with a high-output power supply and a structural
design that has been optimized for maximum usability in a wide range
of applications. The chassis’ modular design ensures a high level of
maintainability, resulting in a very low mean time to repair (MTTR).
The NI PXIe-1065 chassis fully complies with the PXI-5 PXI Express
Hardware Specification
, offering advanced timing and synchronization
features.

The key features of the NI PXIe-1065 chassis include the following:

High Performance for Instrumentation Requirements

Up to 1 GB/s (single direction) per PXI Express slot dedicated
bandwidth (x4 PCIe)

30 W per slot cooling meets increased PXIe cooling requirements

Low-jitter internal 10 MHz reference clock for PXI slots with
± 25 ppm stability

Low-jitter internal 100 MHz reference clock for PXIe slots with
± 25 ppm stability

Quiet operation for 0 to 30 °C at 43.6 dBA

Table 1-1. AC Power Cables

Power Cable

Reference Standards

Standard 120 V (USA)

ANSI C73.11/NEMA 5-15-P/IEC83

Switzerland 220 V

SEV

Australia 240 V

AS C112

Universal Euro 230 V

CEE (7), II, IV, VII IEC83

North America 120 V

ANSI C73.20/NEMA 5-15-P/IEC83

United Kingdom 230 V

BS 1363/IEC83