Nortel Networks SRG 50 NN43001-307 User Manual
Page 120
120
Bandwidth Management
Command
Description
Configure the zone-to-zone record validity time interval, where:
•
Zone = 1-255
•
Interval = 1-(48)-255
CHG CD <Zone> <Cd>
Change the Cd coefficient in the formula that determines how quickly an alarm
reduces the Sliding Maximum bandwidth for the identified zone, where:
•
Zone = 1-255
•
Cd = Cd coefficient = 1-(50)-100
CHG CPL <Zone> <Cpl>
Change the Cpl coefficient in the formula that determines how quickly an alarm
reduces the Sliding Maximum bandwidth for the identified zone, where:
•
Zone = 1-255
•
Cpl = Cpl coefficient = 1-(50)-100
CHG CJ <Zone> <Jitter>
Change the Cj coefficient in the formula that determines how quickly an alarm
reduces the Sliding Maximum bandwidth for the identified zone, where:
•
Zone = 1-255
•
Jitter = Jitter coefficient = 1-(50)-100
CHG CQOS <Zone> <QoS>
Change the QoS coefficient in the formula that determines how quickly an alarm
reduces the Sliding Maximum bandwidth for the identified zone, where:
•
Zone = 1-255
•
QoS = QoS coefficient = 1-(50)-100
CHG CR <Zone> <Cr>
Change the Cr coefficient in the formula that determines how quickly an alarm
reduces the Sliding Maximum bandwidth for the identified zone, where:
•
Zone = 1-255
•
Cr = Cr coefficient = 1-(50)-100
Nortel Communication Server 1000
Main Office Configuration Guide for SRG 50
NN43001-307
02.02
Standard
Release 5.0
3 December 2007
Copyright © 2005-2007, Nortel Networks
.