NTI VEEMUX VIDEO MATRIX SWITCH

7

CONTROL OPTIONS

The VEEMUX video matrix switch has four methods of control:

• Front Panel LCD with Keypad

• Directly via an RS232 Interface

• Remotely via Ethernet

• Infrared Remote (optional).

Every unit comes standard with the Front Panel LCD with Keypad, and RS232 built in. Rack mount models also include Ethernet
connection. If desired, the Infrared option must be requested at the time of the order. The Infrared option requires the purchase
of a separate remote control device (Infrared transmitter) as well as an Infrared receiver to be installed in the VEEMUX. No
software is involved (see Infrared Control on page 23). With the RS232 option, there are no external devices to be purchased.
NTI provides software commands as well as a test program to ensure the RS232 functions properly (see page 8 – RS232
Control).

Front Panel LCD with Keypad Control

The front panel LCD and keypad allow the user to monitor switch status and route any user to any video source on the switch.
When the unit is powered up, each monitor is automatically connected to the video source of its equal number (i.e. monitor 1 to
source 1, monitor 2 to source 2, monitor 3 to source 3, etc.). Along with the routing of the inputs (video sources) to the outputs
(monitors) the keypad and LCD allow the users to configure the RS-232 control interface. The keypad buttons perform the
following functions.

ESC

Escape back to the main display.

0 – 9

Used to enter numbers. ( # )

OUT

The output user number can be entered

(2 digits or 1 digit and ENTER or IN)

followed by the input

IN

Used following single digit output entries

ENTER Used following single digit entries



Display next 4 outputs and their inputs



Display previous 4 outputs and their inputs

MENU The RS-232 menu is displayed. This allows the baud rate to be set at 9600, 2400, 1200 or 300 baud and the unit

address to be set to 1 - 15. See RS-232 control later in this chapter.

*

Activate Memory Function - 100 memory locations 0 – 99, 0 is the power on default.

to Save current connections ( * ) ( OUT ) ( # ) ( ENTER )

to Recall connections from ( * ) ( IN ) ( # ) ( ENTER )

To set all outputs to one input ( * ) + ( # ) + (ENTER)

The following examples show various method of routing output 3 to input 5. Inputs and Outputs can be entered as a two digit
number or a one digit number followed by IN or ENTER.

(OUT) 3 (IN) 5 (ENTER)

(OUT) 3 (ENTER) 5 (ENTER)
(OUT) 03 05
3 (ENTER) 5 (ENTER)
03 05

Note: If the current switch configuration includes assigned Scan Mode dwell time values (pg. 8), to save the current
configuration be sure to assign a memory location to it. Otherwise, when the VEEMUX is powered OFF, all dwell time
values will be erased. Also, saving the configuration as memory location 0 will cause it to be the power-ON default
configuration.

1

2

3

In

4

5

6

Out

7

8

9

0

*

ESC

ENTER

MENU

IN: 1 2 3 4

OUT: 1 2 3 4

Configurations that are saved into memory locations via
the keypad can be recalled via the web interface (page 18)
and vice versa.