Ethernet operations, Setup options – Network Technologies SM-nXm-15V-LCD User Manual

Page 16

Advertising
background image

NTI VEEMUX VIDEO MATRIX SWITCH

12



Ethernet Operations

Key

Selection

Description

1)

Set Unit IP Address

- enter the desired IP address in xxx.xxx.xxx.xxx format
- number of digits is minimum 1 and maximum 3 for each field. Leading zeroes are
accepted

2)

Set Unit Subnet Mask

- enter the desired IP address in xxx.xxx.xxx.xxx format
- number of digits is minimum 1 and maximum 3 for each field. Leading zeroes are
accepted

3)

Set Unit Default Gateway

- enter the desired default gateway
- number of digits is minimum 1 and maximum 3 for each field. Leading zeroes are
accepted

4)

Set Unit Website Timeout

- set the website timeout; timeout = numeric string of timeout in seconds
- Values: 60, 300, 600, 900, 1800, 3600, 7200, 18000, 28800 0 = no timeout

5)

Read Unit IP Address

- read the unit IP address in xxx.xxx.xxx.xxx format

6)

Read Unit Subnet Mask

- read the unit subnet mask in xxx.xxx.xxx.xxx format

7)

Read Unit Default Gateway

- read the unit default gateway in xxx.xxx.xxx.xxx format

8)

Read Unit Website Timeout

- read the current website timeout period in seconds
- Values: 60, 300, 600, 900, 1800, 3600, 7200, 18000, 28800 0 = no timeout

Setup Options

Key

Selection

Description

1)

select Com port current:
(COM1:)

- select PC serial port
- the current PC serial port is displayed in parentheses

2)

select Baud rate current:
(9600)

- select PC serial port baud rate

- the current baud rate is displayed in parentheses

3)

set unit Address current:
(1)

- select the unit address
- the current address is displayed in parentheses





For any selection that requires user input, the user is prompted. When commands are sent to the matrix unit, the command string
and matrix unit responses are echoed to the screen. All commands generated by the program are formatted according to the
information provided in sections above. If any transmission problems are detected, an error message is displayed.

Press <Esc> or <Enter> to back out to the main menu and press again to exit.