Network Technologies SM-nXm-15V-LCD User Manual

Page 14

Advertising
background image

NTI VEEMUX VIDEO MATRIX SWITCH

10

Command Definitions (Continued)

Command
String

Good Response

Description

RS SW

*<CR>

Internal Reset

RV SW,00

*<CR>string\0<CR>

Read NTI Version String

RU SW

*<CR>IP,OP<CR>

Read Unit Size

EA SW,ip

*<CR>

Set the IP address, ip is in xxx.xxx.xxx.xxx format,
number of digits is minimum 1 and maximum 3 for each field
Leading zeroes are accepted

EM SW,ip

*<CR>

Set the Subnet mask, ip is in xxx.xxx.xxx.xxx format,
number of digits is minimum 1 and maximum 3 for each field.
Leading zeroes are accepted

EG SW,ip

*<CR>

Set the default gateway, ip is in xxx.xxx.xxx.xxx format,
number of digits is minimum 1 and maximum 3 for each field
Leading zeroes are accepted

ET
SW,timeout

*<CR>

Set the website timeout; timeout = numeric string of timeout in seconds.
Values: 60, 300, 600, 900, 1800, 3600, 7200, 18000, 28800
0 = no timeout

RA SW *

<CR>ip<CR>

Read the IP address, ip is in xxx.xxx.xxx.xxx format,
number of digits is minimum 1 and maximum 3 for each field
Leading zeroes are accepted

RM SW *

<CR>ip<CR>

Read the Subnet mask, ip is in xxx.xxx.xxx.xxx format,
number of digits is minimum 1 and maximum 3 for each field
Leading zeroes are accepted

RG SW *

<CR>ip<CR>

Read the default gateway, ip is in xxx.xxx.xxx.xxx format,
number of digits is minimum 1 and maximum 3 for each field
Leading zeroes are accepted

RT SW *

<CR>timeout<CR>

Read the website timeout; timeout = numeric value in seconds.
Values: 60, 300, 600, 900, 1800, 3600, 7200, 18000, 28800
0 = no timeout

SS SW,00

*<CR>

Disable Autostatus feature (see below)

SS SW,01

*<CR>

Enable Autostatus feature (see below)

GO SW,OP

*<CR>go SW,OP:IP<CR>

Read connection of a Output Port to Input Port

GM SW,00

*<CR>go SW,OP:IP (all
ports)<CR>

Read connection matrix of all Output ports

Ss
SW,OP,DWT

*<CR>

Set

Scan Mode

dwell time for specific Output port

DWT values: 000-255 000= scan disabled See page 8 for more info.

Gs SW,OP

*<CR>DWT<CR>

Read scan mode dwell time setting for an Output port
DWT values: 000-255 000= scan is disabled for the port

Sa SW,OP

*<CR>

Set scan list of individual output to all inputs

Sc SW,OP

*<CR>

Clear scan list of individual output

S+ SW,OP,IP

*<CR>

Add individual input to Scan List of output

S- SW,OP,IP

*<CR>

Remove individual input from Scan List of output

Sx SW,OP

*<CR>oooxoxxxooooxxx<CR>

Inspect the Scan List of individual output (o=skip x=don't skip)

If the first field is not a known command (as listed above) or SW field is different from the serial address programmed in the switch
memory, the command will be ignored. If the SW field corresponds to the unit address, but the syntax is wrong after this field, the
switch will answer with a bad response ?<CR>.

Autostatus

When Autostatus is enabled, any output-to-input connection change in the VEEMUX will cause an Autostatus message to be sent
via RS232 to the administrator. The format of the message would be "pc SW,OP:IP<CR>"

Example of an Autostatus message:

pc 01,01:04<CR>

which means "At the switch with unit address 01, the output (01) has changed connection to input 04."

Notes: Message to the administrator will be delayed by any RS232 traffic being received by the switch from the
administrator.
Autostatus must be disabled before using SerTest or the NTI Switch Control Program (below).


By default, Autostatus is disabled and must be manually enabled. Autostatus is also disabled any time the power to the
VEEMUX is interrupted.