13



ETHERNET CONTROL

Telnet Interface-Port 2000


The Telnet Interface enables the user to control the switch using telnet client through an Ethernet connection. The telnet server
listens on ports 2000 and 2005. Port 2000 is for an operator telnet session while port 2005 (must be enabled) is intended for a
software control type session (see page 14). For operator telnet control using the telnet interface and the current IP address,
type the following in a command shell:

telnet 192.168.1.30 2000


The VEEMUX will prompt the user for a password. The user must enter the password followed by <Enter>.

The factory default password is

"admin".

With a proper password sent the VEEMUX will respond with:

Password Successful
Connection Established


The following commands are now available:

Command

Reply

Description

H(elp) or
h(elp)

Displays the list of
commands

Help

CP

User is prompted to
introduce the password
twice

Change password

CS nn,mm

*<CR>

Connect One Output (User Port) To Input (Video source)

CA nn

*<CR>

Connect All Outputs To Input

RO nn

*<CR>mm<CR>

Read Connection For Output.
Returns the number of the input (mm) connected to output nn

CC nn

*<CR>nn<CR>

Save Matrix Connections Into Memory Bank nn
nn should be between 00 and 99

RC nn

*<CR>nn<CR>

Restore Matrix Connections From Memory Bank nn
nn should be between 00 and 99

CB nn

*<CR>

Change baud rate of serial line, nn=12(00),24(00),48(00),96(00)
Factory default is 9,600.

RS *<CR>

Reset

Unit

RV 00

*<CR>string\0<CR>

Read NTI Version String

RU

*<CR>nn,mm<CR>

Read Unit Size
Returns the number of inputs(nn) and the number of outputs (mm)

Ss nn,dwt

*<CR>

Set value of Scan Mode dwell time (see pg. 8) for specific Output (nn)
dwt = 000-255 (seconds) 000= disable Scan Mode

Gs nn

*<CR>
dwt<CR>

Read set Scan Mode dwell time value (dwt) for specific Output (nn) in
seconds (see also "Scan Mode" on page 8)

Sa nn,mm

*<CR>

Set scan list of individual output nn to all inputs mm

Sc nn

*<CR>

Clear scan list of individual output nn

S+ nn,mm

*<CR>

Add input mm to Scan List of output nn




Advertising