Installation

52

D-73d Series Installation/Operation Manual

PRE

L

IMINAR

Y

DHD

1.

Select Calibration -> Adjustment Mode
and set it to Secondary.

2.

Select Service -> Test Video and choose
Secondary Alignment.

Projector (Align Secondary/Right
Image with Screen)
1.

Align the image to the screen by
adjusting the Right (bottom) primary
lens zoom, focus and H/V offset.

2.

Tighten the Right primary lens lock
screw.

3.

D-73d/CineWide with AutoScope
only: Remove anamorphic lenses.
Set the AutoScope transport motor
AC switch to the “on” position.

Note: The default warp is 46 pixels on
the left and right sides (x) and 26 pixels at
the top and bottom (y). If more is
needed, use the “Image Alignment”
controls to increase it.

DHD
1.

For a ceiling-mounted (inverted) and/or
rear-projection installation, select
Service -> Display Device ->
Configure -> Installation ->
Picture Orientation
and set it as needed.

2.

Select Aspect Ratio and set it to Cinema.
On a D-73d/CineWide with AutoScope, this
should position the anamorphic lens
transport in front of the primary lenses.

3.

Select Calibration -> Adjustment Mode
and set it to Primary.

4.

Select Service -> Test Video and choose
Primary Alignment.

Projector
1.

(Re-)install anamorphic lenses.

2.

Align the primary (left-eye) image with
the screen by adjusting the Left (top)
anamorphic lens to produce the least
amount of distortion.

DHD
1.

Select Calibration -> Adjustment Mode
and set it to Secondary.

2.

Select Service -> Test Video and choose
Secondary Alignment.

Projector
1.

Align the secondary (right-eye) image
to the screen by adjusting the Right
(bottom) anamorphic lens to produce
the least amount of distortion.

DHD (Align Secondary Image with Primary
Image)
1.

Select Aspect Ratio and set it to 16:9.

2.

Select Calibration -> Adjustment Mode
and set it to Secondary.

3.

Select Calibration -> Image Alignment
-> Corner Alignment
, check the Primary
Test Pattern
and Secondary Test
Pattern
boxes and adjust corners.

4.

Select Calibration -> Image Alignment
-> Midpoint Alignment
, check the
Primary Test Pattern and Secondary
Test Pattern
boxes and adjust midpoints.

Projector

No adjustment needed.

Note: The Primary lens image is usually
left un-warped. This provides the best
image quality and will be un-scaled for
1080p sources. You can adjust the
Primary image if needed, however, by
setting the Adjustment Mode to
Primary, checking the Primary Test
Pattern
and Secondary Test Pattern
boxes and adjusting the corners and/or
midpoints prior to this step.

Table 3-6. D-73d Optical Alignment Procedure (with Anamorphic Lenses) (continued)