Initial Scanner Setup

100

9

Depending on how the original
is positioned, the scan area will
be as follows:

The range of possible original
sizes and scan sizes is as fol-
lows:
• Original Size

X1: 210-914 mm (8.3”-36.0”)
Y1: 210-15000 mm (8.3”-11.7”)

• Scan Area

X3: 10-914 mm (0.4”-36.0”)
Y3: 10-15000 mm (0.4”-590.6”)

Keep the scan area settings
within these ranges.

D When all dimensions are en-

tered, press [OK].

E Make sure that the area speci-

fied in step

D

D

D

D (X3 and Y3) is

shown in the [Custom Size]
field, and then press [OK].

Automatically Detecting the
Vertical Measurement (Length)

A Press [Auto Detect].

B Using the number keys, enter

the horizontal measurement
(width) of the original.
Select [X1], enter the horizontal
measurement, and then press
the

{{{{#}}}} key.

When you automatically detect
t h e v e r t i c a l m e a s u r e m e n t
(length) you can specify only
[X1]

. [X2] is set to “0”, and [X3] is

set to the same value as [X1].