9

You can perform screen operations by using the function keys while the File
Selection Display is displayed.

Function key

Name

Function

Page

F1

Copy

Copies previously created screen data to another screen number.

90

F2

Delete

Deletes designated screen data. Can also be used to delete
multiple screens, or to delete screens from the Programmable
Terminal one screen at a time.

91,
114

F3

Print

Prints designated screen data. Can also be used to print multiple
screens.

101

F4

Attribute Change
(ATTRIB)

Sets buzzer attributes, bit inputs, history records, and alarms.

78

F5

Read

Loads screen data from other files. The data can include screens,
marks, the numeral table, the character string table, I/O
comments, and direct connection information.

93

F6

Transmit (TMX.)

Transmits data from the Support Tool to a Programmable
Terminal. The data to be transmitted can be a single screen,
multiple screens, or a memory table.

108

F7

Receive (RCV.)

Receives data sent from a Programmable Terminal to the
Support Tool. The data to be received can be a single screen,
multiple screens, or a memory table.

111

F8

Continuous or
Overlapping Screen
Creation (Co/Ovl)

Creates Continuous or Overlapping Screens.

75

F9

Marks (MARK)

Creates and modifies marks.

82

F10

Next Item (NEXT)

Use to change the functions allocated to the function keys.

---

NEXT, F1

Comment Change
(CMNT)

Changes screen comments that have previously been set.

92

NEXT, F2

Table Edit (TABLE)

Edits memory tables

59

NEXT, F3

Check (CHECK)

Checks whether there are any errors in continuous or overlapping
screens, and displays or prints the results.

80

NEXT, F4

Direct Connection
(DIRECT)

Sets data area allocations, comments, and other information for
use with direct connection operation. This function key appears
only if direct connection has been turned ON in the Tool Settings.

17

NEXT, F10

Previous Item (PREV)

Use to change the functions allocated to the function keys.

---

Tags can be used to handle multiple screens simultaneously. For example,
several screens can be deleted at the same time by tagging them and then
executing

Delete from the Screen Selection Display.

Use the following keys to attach or remove tags.

Key(s)

Operation

Space

Reverses the tag of the screen with the bar cursor.

Home

Clears all tags.

Shift+Home

Reverses all tags.

Tags are indicated by asterisks. By using tags effectively, you can handle
multiple screens as a single group.

Screen Selection
Operations

Handling Multiple Screens

Screen Selection