Omron NT20M User Manual

Page 68

Advertising
background image

64

When the initial value is designated, the number of digits input and the num-
ber of digits transmitted to the host are set.

Input and Transmission Digits

Input digits
(Input Col)

Set the number of digits that can be input via touch switches or
function keys. You can set from 1 to 8 digits.

Transmission
Digits
(Sending)

Set the number of digits that are transmitted to the host. You can
select either 4 or 8 digits.

Numeral
Display (Num
Disp)

Select whether or not numeral display is to be set at the same
time as numeral editing.

Press the Enter Key after making all the settings.

If Numeral Display is set to “Yes,” the Numeral Display Settings Display will
be displayed automatically. Set the numeral display as required.

If Numeral Display is set to “No,” you will be returned to the selection of the
memory table for writing.

Numeral Editing

Section 2-8