69

Heading

Meaning

No.

Numeral table entry number

Contents

Initial value

IN (initialize at startup)

Indicates whether or not the table value is to be
initialized when the PT is turned ON.

# (quantity)

Number of PC words used

Word

Address of the first PC word

Comment

User comment area

4.

Input the desired initial value. This value can be omitted here if desired
and input later using the table edit operation. The initial value can be up
to 8 digits long. When the initial value field is left, the following display
will appear to input the remaining settings.

Note Negative values and initial values are set differently for direct connection.

Refer to page 61 for details.

5.

Make the four settings as described in the following table. The comment
is optional and all four settings can be omitted here if desired and input
later using the table edit operation.

Heading

Meaning

Initialize (Init)

Set YES to initialize the contents in the numeral
table when PT power is turned ON. Set to NO to
maintain the previous value when PT power is
turned ON.

Set words (St Word)

Set the number of PC words to be used.

Word

Set the address of the first PC word to be used.

Comment

Input any desired user comment area

Numeral Editing

Section 2-8