Omron NT20M User Manual

Page 48

Advertising
background image

44

nate the center and one point on the circumference of the circle. A dis-
play will appear to specify the bit that is to control the lamp.

5.

Input the address of the PC bit that is to control the lamp. Timer/counter
numbers cannot be specified. DM word address can also be specified,
followed by the bit number within the word.

6.

Input a comment if desired. The comment is for user use only. The lamp
settings will appear when the above display is left.

7.

Set the way in which the display will appear on the screen.

Frame

Whether or not lamp frames are to be displayed when lamps are
displayed. If “No” is designated, lamps will be indicated by dotted
lines on the Support Tool display.

Attributes

Set whether the lamp will light or flash when controlled by bit
signals from the host.

This attribute is effective only when controlling the lamp via bit
signals from the Host Interface Units that support bit designation.
This setting is ignored when controlling lamps via commands,
which can be used to control the same attribute.

Label

Whether or not a label is to be attached to the lamp.

Lamps

Section 2-4