2100 Millennium Wood Stove (ACC)

B. Outside Air Kit Installation

1. Remove all materials from packing box.
2. Using a #2 Phillips screw driver attach the flex adapter to

the stove using 4 screws.

Figure 12.1.

3. For floor installations, remove circular “knock-out” in the

base of the pedestal.

Figure 12.1.

4

.

Floor & Rear Installation: Cut a 4 inch (102mm) hole in

outside wall or floor to accommodate outside air piping.

Use 4 inch (102mm) aluminum metal flex or rigid piping

to directly connect outside air to appliance intake. Use

the supplied termination cap with a rodent screen. Seal

between the wall (or floor) and the pipe with silicone to

prevent moisture penetration.

Included in OAK-ACC:

Termination cap, (2) wire ties, flex

adapter, and fasteners

Included in SRV7033-041:

Cover plate and sealing rope (see

Floor Installation Alternative below,

Figure 12.2)

Items Needed for Installation (not supplied)

• 4 inch flex aluminum pipe, or if using alternate material,

then it shall be made from durable, non-combustible, heat

resistant material up to 350

o

F. Cut the pipe to the required

length for your installation.

• Phillips head screw driver
• Silicone sealant

• Drills and saws necessary for cutting holes through the

wall or flooring in your home

Figure 12.1 - Floor & Rear Installation

A source of air (oxygen) is necessary in order for combus-

tion to take place. Whatever combustion air is consumed

by the fire must be replaced. Air is replaced via air leakage

around windows and under doors. In homes that have tightly

sealed doors and windows, an outside air source is needed.

An optional Outside Air Kit is available.

Flex Line

Wire Tie

Wire Tie

Flex Adapter

Termination

Cap

For Floor Installa-

tions Remove

Circular “Knock-Out”

in Base of Pedestal.

WARNING

Do not draw outside combustion air from:
• Wall, floor or ceiling cavity
• Enclosed space such as an attic or garage
• Close proximity to exhaust vents or chimneys
Fumes or odor may result

Fire Risk.
Asphyxiation Risk.

Asphyxiation Risk.
Outside air inlet must be located to prevent blockage

from:
• Leaves
• Snow or ice
• Other debris
Block may cause combustion air starvation
Smoke spillage may set off alarms or irritate sensitive

individuals.

WARNING

Asphyxiation Risk.
Length of outside air supply duct shall NOT exceed

the length of the vertical height of the exhaust flue.
Fire will not burn properly
Smoke spillage occurs when door is opened due to

air starvation.

WARNING

Figure 12.2 - Floor Installation Alternative

Cover

Plate

5.

Floor Installation Alternative: In some instances you

may not be able to install the flex pipe as show in

Figure

12.1. If that is the case, you will need to order SRV7033-

041 which includes a cover plate and sealing rope as

shown in

Figure 12.2. The goal is to seal the pedestal

so no room air can leak into the pedestal and to seal or

for cold air infiltration.