F. Burn Rates and Operating Efficiency

For maximum operating efficiency
1. This appliance has a timer system (ACC) that operates

the stove at its maximum efficiency removing any guess

work for the homeowner. Follow the instructions below

for each burn rate for the Start-Up Air Control and Burn

Rate Air Control.

Figure 22.1.

2. Burn dry, well-seasoned wood.

Burn Rates
1. Starting a Fire and Reloading

Open both controls fully by raising the Burn Rate Air

Control all the way up until it stops and slide the Start-up

Air Control back until it stops. After loading the stove with

wood and starting the fire, set both controls to the desired

setting by following the burn rate instructions below.

2. High Burn Rate - Maximum Heat

Raise the Burn Rate Air Control all the way up until it stops

(top marker) to a fully open position. Slide the Start-Up Air

Control all the way back until it stops (HI marker) and leave

it there. This setting over-rides the timer system (ACC) so

you must monitor the fire closely while in this setting.

3. Medium-High Burn Rate

-

15,000 to 30,000 BTU/hr

Raise the Burn Rate Air Control all the way up until it

stops (top marker) to a fully open position. Slide the

Start-Up Air Control all the way back until it stops (HI

marker) and then pull forward until it stops. This activates

the timer system (ACC).

2. Burn Rate Air Control
This air supply enters at the upper front of the firebox, near the

top of the glass door. This preheated air supplies the neces-

sary fresh oxygen to mix with the unburned gases, helping

to create second, third and fourth combustions. This air is

regulated by the Burn Rate Air Control. There are four settings

High, Medium-High, Medium-Low and Low. When the control

is raised all the way up it is on the High setting and when

pushed all the down it is on the Low setting.

Figure 22.1.

NOTE: These are approximate settings, and will vary with

type of wood or chimney draft. Due to altitude and other

environmental circumstances, this operational information is

a guideline only.

WARNING

Risk of Fire.
When set on High Burn Rate and over-riding

the Automatic Combustion Control system an

overfire situation can occur and may result in a

chimney fire.
Overfiring will void the stove warranty.

4. Medium-Low Burn Rate - 10,000 to 15,000 BTU/hr

Raise the Burn Rate Air Control up to the bottom of

the middle marker and stop. Slide the Start-Up Air

Control all the way back until it stops (HI marker) and

then pull forward until it stops. This activates the timer

system (ACC).

5. Low Burn Rate - Below 10,000 BTU/hr

Leave the Burn Rate Air Control at the bottom marker.

Slide the Start-Up Air Control all the way back until it

stops (HI marker) and then pull forward until it stops.

This activates the timer system (ACC).

F

igure 22.1

NOTE:

Operate appliance on High Burn 15 minutes a

day to help keep flue/chimney clean.

START-UP

REAR AIR

HI

Closed

Wide

Open

“HI” setting

over-rides

Timer

After activating the timer (ACC), if the control is placed

within the rear air section on the label it will allow rear air

to enter the firebox. This will not interfere with the timer

gradually closing the front air channel in 25 minutes. If

control is set on “HI” it over-rides the timer (ACC).

High (Open)

Low (Closed)

Start-Up Air

Control

Burn Rate

Air Control

Front Air Channel

Operated by Timer

Rear Air Channel

Operates independently

from Timer

HIGH

LOW

Timer

Timer Manual

Shut-off

Shown with Side

Shield Removed