Timer operation – Toshiba RAV-SM561AT-E User Manual

Page 39

Advertising
background image

– 39 –

RAV-SP1100UT-E,
RAV-SM560UT-E, RAV-SM800UT-E, RAV-SM1100UT-E, RAV-SM1400UT-E

TIMER OPERATION

A type of timer operation can be selected from the following three types.

OFF timer

: The operation stops when the time of timer has reached the set time.

Repeat OFF timer : Every time, the operation stops after the set time has passed.

ON timer

: The operation starts when the time of timer has reached the set time.

Timer operation

UNIT

4

1

SET

CL

3

2

1

Push TIMER SET button.

• The timer display (type) changes for every

push of the button.

• SET DATA and

display flashes.

2

Push

to select “SET TIME”.

For every push of

button, the set time increases in the unit of 0.5 hr (30 minutes).

The maximum set time is 72.0 hr.

For every push of

button, the set time decreases in the unit of 0.5 hr (30 minutes).

The minimum set time is 0.5 hr.

3

Push SET button.

• SET DATA display disappears and

display goes on.

(When ON timer is activated, time is displayed, and after time of the timer has been up, displays other

than ON disappear.)

Cancel of timer operation

4

Push CL button.

• TIMER display disappears.

NOTICE

• When the operation stops after the timer reached the preset time, the Repeat OFF timer resumes the

operation by pushing

button and stops the operation after the time of the timer has reached

the set time.

OFF

(OFF timer)

(Repeat OFF timer)

No display

(ON timer)

OFF

ON

Advertising