Wire connection – Toshiba RAV-SM2242DT-E User Manual

Page 27

Advertising
background image

– 26 –

Concealed Duct High Static Pressure

Installation Manual

EN

„ Wire connection

REQUIREMENT

• Be sure to connect the wires matching the terminal numbers. Incorrect connection causes a trouble.
• Be sure to pass the wires through the bushing of wire connection holes of the indoor unit.
• Keep a margin (Approx. 100mm) on a wire to hang down the electrical control box at servicing, etc.
• The low-voltage circuit is provided for the remote controller. (Do not connect the high-voltage circuit)

1. Remove the cover of the electrical control box by taking off the mounting screws (2 positions)
2. Tighten the screws of the terminal block, and fix the wires with cord attached to the electrical control box.

(Do not apply tension to the connecting section of the terminal block.)

3. Mount the cover of the electrical control box without pinching wires.

System interconnecting
wire

Cord clamp

Wired remote
controller wire

Electrical
control box
cover

Fixing screw

Bushing

System
interconnecting
Terminal block

Indoor fan power
supply Terminal
block

<Terminal block of electrical control box>

Wired remote controller
connecting Terminal
block

Indoor fan power supply
wire

26-EN