13 mdio user phy select register 0 (userphysel0), Section 4.13 – Texas Instruments TMS320TCI6486 User Manual

Page 88

Advertising
background image

MDIO Registers

www.ti.com

4.13 MDIO User PHY Select Register 0 (USERPHYSEL0)

The MDIO user PHY select register 0 (USERPHYSEL0) is shown in

Figure 40

and described in

Table 33

.

Figure 40. MDIO User PHY Select Register 0 (USERPHYSEL0)

31

16

Reserved

R-0

15

8

7

6

5

4

0

Reserved

LINKSEL

LINKINTENB

Reserved

PHYADRMON

R-0

R/W-0

R/W-0

R-0

R/W-0

LEGEND: R = Read only; R/W = Read/Write; -n = value after reset

Table 33. MDIO User PHY Select Register 0 (USERPHYSEL0) Field Descriptions

Bit

Field

Value

Description

31-8

Reserved

0

Reserved

7

LINKSEL

Link status determination select bit. Default value is 0, which implies that the link status is
determined by the MDIO state machine. This is the only option supported on this device.

6

LINKINTENB

Link change interrupt enable. Set to 1 to enable link change status interrupts for PHY address
specified in PHYADRMON. Link change interrupts are disabled if this bit is set to 0.

0

Link change interrupts are disabled

1

Link change status interrupts for PHY address specified in PHYADDRMON bits are enabled

5

Reserved

0

Reserved

4-0

PHYADRMON

PHY address whose link status is to be monitored.

88

C6472/TCI6486 EMAC/MDIO

SPRUEF8F – March 2006 – Revised November 2010

Submit Documentation Feedback

Copyright © 2006–2010, Texas Instruments Incorporated

Advertising