Toshiba PORTEGE M400 User Manual

Page 135

Advertising
background image

3.4 Setting of the hardware configuration

3 Tests and Diagnostics

PORTEGE M400 Maintenance Manual (960-541)

[CONFIDENTIAL]

3-17

Setting of the HWSC
Setting of the UUID
Display of the DMI information (including UUID)
Setting of DVD region code (Yes/No)

After completion of the above settings, H/W configuration & DMI
information are appeared in order. Check the contents and press Enter.

Following message appears in the display. Press any key, then return to the
H/W initial information setting tool menu.

+------------------------------------------------+

+ It switches off the power on automatically. +

+------------------------------------------------+
Press

any

key

to

continue...

Subtest 03

DMI information save

NOTE: Before replacing the System board, be sure to execute this subtest and save the

DMI information to the floppy disk.

This is one of tools to copy the DMI information to a new PCB after
replacing.

This subtest saves all the DMI data in a floppy disk.

Subtest 04

DMI information recovery

NOTE: 1. After replacing the System board, be sure to execute this subtest and copy the

DMI information to a new System board.

2. Since the data of UUID is updated every time when this subtest, DMI

information recovery, is done, the saved UUID data is not written.

This is one of tools to copy the DMI information to a new PCB after
replacing.

This subtest writes all the DMI data in the floppy disk into the new PCB.

Advertising