Toshiba PORTEGE M400 User Manual

Page 417

Advertising
background image

Appendix J Maintenance of TOSHIBA RAID

Appendices

Check Media

This option can check if there is an error in the HDD of array. The Check Media can be
done only in RAID-1. To execute Check Media, follow the procedure below.

1. Put the cursor to the [Check Media] in [Main Menu] and press Enter key.

2. When [Check Range] is displayed, designate the range to be checked. When

[Effective] is limited, it makes the rebuild limit effective and execute [Check
Media] up to the rebuild limit. When [Whole] is selected, execute [Check Media]
up to the maximum capacitor of RAID array. The [Rebuild Range] menu is not
displayed when the rebuild limit is not set or the rebuild limit is the same as the
maximum capacity of array. Normally designation of [Effective] is adequate.

3. To start the Check Media, put the cursor to the [Confirmation] and press Enter

key. When an error is detected, it automatically correct.

4. During [Check Media], the progress rate, expected remaining time and the number

of errors are displayed in [Progress] of [Physical Drive], [Check Media] may take
time depending on the drive capacity.

5. When [Check Media] is completed, put the cursor on [OK] and press Enter key to

return to the menu of Independent Utility.

The date when the [Check Media] was done last is displayed in [Last MC] of [Logical
Drive]. [Last MC] is renewed when rebuilding is done. When “Rebuild Limit” is
changed or right after building RAID array, the value of [Last MC] becomes [00/00/00].

PORTEGE M400 Maintenance Manual (960-541)

[CONFIDENTIAL]

J-19