Toshiba PORTEGE M400 User Manual
Page 331
Advertising
4.31 Fluorescent lamp
4 Replacement Procedure
Attaching the tapes and insulation sheet
1. Attach the double-sided tape of insulation sheet (1).
2. Attach one bezel tape (2).
2. Attach two bezel tapes (3).
CAUTION: When attaching tape and insulation sheet, be careful not to damage the
PCB, cell and B/L.
Figure 4-64 Replacing 12.1 Inch TMD fluorescent lamp (12)
PORTEGE M400 Maintenance Manual (960-541)
[CONFIDENTIAL]
4-93
Advertising