Toshiba VF-FS1 User Manual
Page 189

E6581381
H-3
8
(Continued)
Item displayed
Key
operated
LED
display
Communic
ation No.
Description
Past trip 1
QE
⇔
FE10
Past trip 1 (displayed alternately)
Past trip 2
QJ
⇔
FE11
Past trip 2 (displayed alternately)
Past trip 3
QR
⇔
FE12
Past trip 3 (displayed alternately)
Past trip 4
PGTT
⇔
FE13
Past trip 4 (displayed alternately)
Parts replacement
alarm information
O___K
FE79
The ON/OFF status of each of the cooling fan,
circuit board capacitor, main circuit capacitor of
parts replacement alarm or cumulative operation
time are displayed in bits.
ON:
OFF: _
Cumulative
operation time
V
FE14
The cumulative operation time is displayed.
(0.01=1 hour, 1.00=100 hours)
Default display
mode
The operation frequency is displayed (Operation at
60Hz).
Note 6
Note 7
Note 8
Note 6
Note 6
Note 6
operation
O
___K
Cooling fan
Cumulative
time
Control circuit board capacitor
Main circuit capacitor
MODE