Toshiba VF-FS1 User Manual

Page 80

Advertising
background image

E6581381

E-14

5

Default setting (V[R = )

Setting V[R to  will return all parameters to the standard values that were programmed at the factory.
⇒ See section 4.2.7.
+

When 3 is programmed, <KPKV will be displayed for a short time after setting and will then be erased
and displayed the original indication .. Trip history data will be cleared at this time.

Trip clear (V[R = )

Setting V[R to  initializes the past four sets of recorded error history data.
+

The parameter does not change.

Cumulative operation time clear (V[R = )

Setting V[R to  resets the cumulative operation time to the initial value (zero).

Cumulative operation time clear (V[R = )

Setting V[Rto  clears the trips when an GV[R format error occurs. But if the GV[R displayed, call us.

Save user setting parameters (V[R = )

Setting V[R to  saves the current settings of all parameters.
⇒ See section 4.2.8.

Load user setting parameters (V[R = )

Setting V[R to  loads parameter settings to (calls up) those saved by setting V[R to .
⇒ See section 4.2.8.
+

By setting V[R to  or , you can use parameters as your own default parameters.

Cumulative fan operation time record clear (V[R = )

Setting V[R to  resets the cumulative operation time to the initial value (zero).
Set this parameter when replacing the cooling fan, and so on.