Ex.2 – Toshiba VF-FS1 User Manual

Page 53

Advertising
background image

E6581381

C-7

3

Remote mode selection,

Operation frequency setting, running and stopping using external

signals.

(1) Wiring

(2) Parameter setting

Title

Function

Setting value

EOQF

Command mode selection

0

HOQF

Frequency setting mode selection 1

1or2

(3) Operation

Run/stop: ON/OFF input to F-CC, R-CC. (Set SW4 to Sink logic)
Frequency setting: VIA and VIB: 0-10Vdc (External potentiometer)

VIA: Input 4-20mAdc.

Use the VIA (SW3) slide switch to switch between voltage and current to the VIA terminal.
Voltage input: V side
Current input: I side

+

Please turn off the lamp by pressing the key when the LOC/REM key lamp is lit.

Control
circuit

Motor

IM

F

R/L1

S/L2

T/L3

U/T1
V/T2

W/T3

Run forward signal

R

PC/-

PA/+

Power circuit

Run backward signal

MCCB

CC

Common

CC

VIB

VIA

PP

Voltage signal: 0

∼10V, Current signal: 4∼20mA

External potentiometer

(Otherwise, input voltage signal (0~10V) between the terminals VIA-CC.)

Noise