13 preset-speed operation (speeds in 7 steps) – Toshiba VF-FS1 User Manual

Page 94

Advertising
background image

E6581381

E-28

5

105

%

110

%

Output current [%]

Time [sec]

60

Inverter overload

0

100% = inverter rated output current

0.25

185

%

Inverter overload protection characteristics

* To protect the inverter, overload

trip or overcurrent trip activate in
a short period of time when
output current reaches 110% or
higher.

4) Thermal memory selectionH

At the main power off, it is selectable whether retention of electric thermal calculation values or not.



: Incase of not activated

The calculated value of the electric thermal is not memorized at power-off.
The calculated value of the electric thermal and the trip state can always be reset.
Don’t reset the unit trip state continually, it may cause the motor and the unit failure.



: In case of activated

The calculated value of the electric thermal is memorized at power-off.
The trip state can always be reset but the calculated value of the electric thermal can not be reset.

5.13 Preset-speed operation (speeds in 7 steps)

UT

- UT : Preset-speed operation frequencies 1-7

• Function

A maximum of 7 speed steps can be selected just by switching an external contact signal. Multi-speed
frequencies can be programmed anywhere from the lower limit frequency NN to the upper limit frequency
WN

.

[Setting method]
1)

Run/stop
The starting and stopping control is done from the terminal board.

Title

Function

Adjustment range

Setting value

EOQF

Command mode selection

0: Terminal board
1: Operation panel
2: Serial communication

0

Note:If speed commands (analog signal or digital input) are switched in line with preset-speed operations, select

the terminal board using the frequency setting mode selection HOQF.

⇒ See step 3) or section 5.3.