E6581381

B-7

2

Terminal

symbol

Input/output

Function

Electrical

specifications

Inverter internal circuits

PP

Output

Analog power supply output

10Vdc

(permissible load

current: 10mA)

VIA

Input

Multifunction programmable analog input.
Factory default setting: 0~10Vdc/0~60Hz
(0~50Hz) frequency input.
The function can be changed to
4~20mAdc (0~20mA) current input by
flipping the VIA (SW3) dip switch to the I
position.

By changing parameter setting, this
terminal can also be used as a
multifunction programmable contact input
terminal. When using the sink logic, be
sure to insert a resistor between P24-VIA
(4.7 k

Ω-1/2 W). Also move the VIA (SW3)

dip switch to the V position.

10Vdc

(internal impedance:

30k

Ω)

4-20mA

(internal impedance:

250

Ω)

VIB

Input

Multifunction programmable analog input.
Standard default setting: 0~10Vdc/0~60Hz
(0~50Hz) frequency input.
PTC thermal input

⇒ See section 6.17.15.

10Vdc

(internal

impedance: 30k

Ω)

FM

Output

Multifunction programmable analog
output. Standard default setting: output
frequency.
The function can be changed to 0-20mAdc
(4-20mA) current output by flipping the FM
(SW2) slide switch to the I position.

1mAdc full-scale
ammeter or 7.5Vdc
(10Vdc)1mA full-
scale voltmeter

0-20mA (4-20mA)
DC ammeter

Permissible load
resistance:
750

Ω or less

P24

Output

24Vdc power output

24Vdc-50mA

* PTC (Positive Temperature Coefficient) : Resettable thermal fuse resistor for over current protection

*