Importing Image Data, Edit Lists

Edit List File Format

Edit list files are text files with the “.edl” filename extension. Composition is as follows:

Header:

PIONEER-DVDRec-EDL 002 ENCODING=XXX

Entry:

Number

Operation Type

Parameter 1

Parameter 2

Parameter 3

The number of parameters differs depending on the type of operation involved. Numbers are consecutive
numerals beginning from 001.

Use a single-byte space (0x20) or tab (0x09) between [PIONEER-DVDRec-EDL] and [002]. Alternately, a carriage
return character (0x0A, 0x0D0A, 0x0D) may also be used.

The message ENCODING=XXX indicates the character encoding, and may be omitted.

The “XXX” represented here supports utf8, eucJP, Shift-JIS, and JIS7. If the command is omitted, utf8 will be
used as default encoding.

IN/OUT Point Setting Entry

Number

Operation Type

Parameter 1

Parameter 2

Parameter 3

NNN

REC

IN Point

OUT Point

Post-REC action

The IN/OUT point is set using time code format as follows: HH:MM:SS:FF
Post-REC action will indicate either STOP or PAUSE.
The final IN/OUT point setting entry in an edit list must always designate the post-REC action as STOP.

Chapter Point Setting Entry

Number

Operation Type

Parameter 1

NNN

CHP

CHAPTER POINT

The chapter point is designated using time code as HH:MM:SS:FF. The chapter point description must come
immediately below the IN/OUT point setting to which it is applied. Also, the Number value is given as that
given to the IN/OUT point setting entry.

DVD-RW disc initialization

Number

Operation Type

NNN

INI

Initialization can be applied only at the head of an edit list entry.

Finalize

Number

Operation Type

NNN

FNL

Finalizing can be applied only as the final entry of an edit list.

Wait

Number

Operation Type

Parameter

NNN

WAI

Comment

The wait command can be used within a list, to designate points necessary to change a VTR tape, etc.

If a comment is input, the comment will appear in the wait dialog.

If the comment is separated by a tab (0x09), it will appear split into two lines at the point of the tab.

Designating the Encoding Parameter

Number

Operation Type

Parameter 1

Parameter 2

NNN

SET

Rate

Filter

Rate is R:n (n= 1-32)

Filter is F:n (n= 0-16)

This setting will continue to be reflected after EDL execution.