Operating Your Vanguard 7300

4-17

Vanguard 7300 Port Configuration

Dynamic Modem
Parameter

This is a description of the Dynamic Modem parameter:

Warning

For digital interfaces the timing must be traceable back to the same clock source and/
or a Stratum 1 clock. If this is not true frame slips will occur causing the modem
traffic to loose some data. However, if the modem is using some type of error
correction and/or the modem is transporting a protocol that has error correction
(such as PPP) the clock slips will have less impact.

Warning

Modem traffic over a QUAD FXS or FXO will not run error free. The QUAD FXS
and FXO run from an internal oscillator. There is no clock synchronization between
the QUAD FXS or FXO and any other voice interface. The amount of errors and the
error rate is dependent on how close the internal oscillator is and cannot be
determined in advance. However, if the modem is using some type of error
correction and/or the modem is transporting a protocol that has error correction
(such as PPP) the errors will have less impact.

Dynamic Modem

Range:

Enabled, Disabled

Default:

Disabled

Description:

Enable or Disable the feature of the dynamic switching to G.711
after modem detection.

If Enabled, the DSP which detects the modem tone switches to
codec G.711 regardless of the codec configured.

Advertising