Vanguard Managed Solutions Vanguard 7300 Series User Manual

Page 63

Advertising
background image

Vanguard 7300 Enclosures and Components

2-31

Vanguard 7300 Cards

Rear Panel LEDs

The T3/E3 Rear Transition Module offers four LEDs to provide operation and
system status information:

Cabling

Refer to Appendix B, Vanguard 7300 Cable Connectors and Pinouts for T3/E3 Rear
Transition Module cabling.

LED

Color

Indication

CSU - Status

Amber

• OFF - The module has failed internal startup check

• ON - Normal module operation

• Flashing - loopback is active (internal or line)

Rx - Status

Amber

• OFF - The module is currently booting and not active

• ON - Normal receive

• Flashing - Receive failure state. The number of flashes between

pauses indicates these types of errors:

– 1 = Alarm Indication Signal (AIS) if received for 2 seconds. If

absent for 10 seconds, the signal is gone

– 2 = IDLE (T3/E3)

– 3 = Remote Alarm Indicator (RAI) if received for 1 second. If

absent for 1 second, the signal is gone

– 4 = Loss of Frame (LOF) or Out of Frame (OOF) if received for

2 seconds. If absent for 10 seconds, the signal is gone

– 5 = Loss of Signal (LOS) if received for 2 seconds. If absent for

10 seconds, the signal is gone

– 6 = Loss of Lock (LOL) if received for 2 seconds. If absent for

2 seconds, the signal is gone

LCD - State

Amber

• OFF - Normal ATM cell delineation

• ON - Loss of cell delineation

USR - Manually Set

Amber

• OFF - Not Used