Vanguard 7300 Installation

3-25

Connecting Vanguard 7300 DC Power

Wiring a Vanguard
7330 DC Power
Supply

Use the procedures in this table for connecting DC power to the dual input terminal
blocks on a Vanguard 7330 Version 1 :

Note

Obtain UL/CSA-approved power cables and connectors with insulated crimp-on
terminals. Power cables must be rated for at least 8A input current. Use cable
harnesses and terminal-connector assemblies that conform to applicable
electrical codes.

Step

Action

1

Be sure the Power On/Off switch on the front panel is in the Off position.

2

Connect the primary power input wires to the two terminals marked -48
and INPUT RTN on the left of the terminal blocks.

3

IMPORTANT: Connect the ground wire to the ground terminal with
the ground symbol at the right side of the terminal blocks.

4

Connect the power cables to the DC power sources.

5

Turn the Power On/Off switch on the front panel to the On position to
apply power to the Vanguard 7330.

6

Observe the DC OK LED at the rear of the power supply, under the
terminal blocks. LED status shows:

• LED illuminated, the power supply is operating properly

• LED not illuminated, power supply is not operating properly