Operating ac appliances – Xantrex Technology XPower Powerpack 400 Plus User Manual

Page 38

Advertising
background image

Operation

3-12

975-0162-01-01

Operating AC Appliances

Low-Battery Alarm

While in use, when the battery reaches 11 Vdc, the
Low-Battery Alarm will sound indicating that battery is
low the unit is about to be shutdown to prevent battery
damage.
When the battery reaches 10.5 Vdc, the unit will
automatically disconnect power to the AC outlets.
If the alarm sounds, disconnect any loads that may be in
use and recharge the unit as soon as possible.

Figure 3-6 Operating AC Appliances

1. Check the State-of-charge to ensure
the battery is fully charged.

2. Open the AC Outlet cover and turn th
power switch to ON. The switch will
illuminate to indicate that power is
available at the AC outlets.

3. Plug the AC appliance into one of th
AC outlets and turn the appliance on.

4. Recharge as soon as possible.

When the ON/Off Switch is turned on,
the output power (watts) display can
be turned off to save power by
pressing the Display Button.

975-0162-01-01_Rev-C.book Page 12 Friday, October 20, 2006 10:40 AM

Advertising
This manual is related to the following products: