Troubleshooting Reference

975-0162-01-01

5-5

Green
Charging
Status
light is
still flashing
and hasn’t
changed to
steady after
50 hours of
charging.

The voltage at the AC
wall outlet is less than
120 Vac.

Internal battery is
permanently damaged.

Use AC wall outlet that supplies
120 Vac.

Replace the battery.

The
compressor
runs but won’t
inflate.

The valve connector
may not be securely
placed on the valve
stem.

The item being
inflated may have a
leak.

Check that the valve connector is
securely placed on the valve stem
before closing the thumb latch.

Check that the item being inflated
has no leaks.

Check the compressor hose for any
breaks or leaks at connections.

The engine
being jump-
started will not
start.

XPower Powerpack
battery is not fully
charged.

The engine condition
is poor.

External fuse (250 A)
is blown.

The engine start
capacity exceeds the
XPower Powerpack
jump-start capability.

Recharge the XPower Powerpack
battery.

Have the engine serviced.

Replace 250 A, 32 V fuse with same
type and ratings.

Table 5-1 Troubleshooting reference

Problem

Possible Cause

Solution