2 ipr, Ipr card frame relay network – Zhone Technologies 600 User Manual

Page 213

Advertising
background image

Server Cards

8-5

IPR Card

Frame Relay Network

8.3.1.2

IPR

The IPR Card can be used for connecting IP nodes on Ethernet to the IP nodes on Frame Relay
Network.This is used for network management solutions. Figure 8-3 shows how the IPR card
is used to connect IP nodes on Frame Relay Network.

Figure 8-3. IPR Card Connected to IP Nodes on Ethernet to Frame Relay Network

Frame Relay

Network

CAU

TION

: Fo

r co

ntin

ued

pro

tecti

on

agai

nst

fire

,

rep

lace

on

ly wi

th th

e sam

e

typ

e an

d rat

ing

of

fuse

Pre

mis

ys C

ommu

nica

tion

s, Inc.

Mod

el IM

ACS

/600

T 5A

250

V

IEC

Fus

e

5A SB

250

V

UL/CS

A

24/48

V

5A

LISTED

9K09

LR 7

706

3

120-

200-2

40V

~

3A,

50 /

60 H

z

Tele

pho

ne

Equipm

ent

Class

2 Po

wer

Sour

ce

®

®

UL

+ -

+ -

+ -

R
G
R

C
O
M

VN

VB

VA

HSU-

T

530

/35

S 6

0

HSU

-T

530

/35

S

60

HSU

-T

530

/35

S

60

HSU-

T

530

/35

S

60

HSU

-T

530

/35

S

60

HSU

-T

530/

35

S 6

0

BRI

HSU
530

/35

S

60

P

2

P

1

P

4

P

3

FXO

813

9

N

O

D

E

T

E

R

M

C

O

M

P

P

1

P

1

CPU
CLO

CK

NVRAM

W1

-1

CSU

W1

-2

DSX

WAN

IF

T1+

DS1

IAD w/IPR

CAUTION:

For

con

tinu

ed

pro

tecti

on a

gain

st fir

e,

replac

e onl

y with the same

type

and rating of fuse

Prem

isys

Co

mm

unic

atio

ns,

Inc.

Mode

l IMA

CS/6

00

T 5A

250

V

IEC

Fuse

5A

SB

250V

UL/

CSA

24/48V

5A

LISTED

9K

09

LR 77

063

120-2

00-240V~

3A, 50 / 60 H

z

Telepho

ne

Equ

ipm

ent

Class

2 P

owe

r So

urce

®

®

UL

+ -

+ -

+ -

R
G
R

C
O
M

VN

VB

VA

HSU

-T

530

/35

S

60

HSU-T

530/

35

S

60

HSU

-T

530

/35

S

60

HSU-T

530

/35

S

60

HSU

-T

530

/35

S

60

HSU

-T

530/35

S

60

BRI

HSU
530

/35

S 6

0

P

2

P

1

P

4

P

3

FXO

8139

N

O

D

E

T

E

R

M

C

O

M

P

P

1

P

1

CPU
CLO

CK

NVR

AM

W1-1

CSU

W1-2

DSX

WA

N
IF

T1+

DS1

IAD w/FRS or IPR

CAUTION:

For co

ntin

ued

prote

ction a

gainst fir

e,

replace onl

y wit

h th

e same

typ

e an

d rati

ng o

f fu

se

Pre

mis

ys Comm

unications

, Inc.

Mod

el IMA

CS/600

T 5A

250V

IEC

Fuse

5A

SB

250V

UL/

CSA

24/48

V

5

A

LISTE

D 9

K09

LR 77

063

120-2

00-240V~

3A, 50 / 60

Hz

Teleph

one

Equip

ment

Class

2 P

owe

r Source

®

®

UL

+ -

+ -

+ -

R
G
R

C
O
M

VN

VB

VA

HSU

-T

530

/35

S

60

HSU-T

530/

35

S

60

HSU

-T

530

/35

S

60

HSU

-T

530

/35

S

60

HSU

-T

530

/35

S 60

HSU

-T

530/35

S

60

BRI

HSU
530/35

S 6

0

P

2

P

1

P

4

P

3

FXO

813

9

N

O

D

E

T

E

R

M

C

O

M

P

P

1

P

1

CPU
CLO

CK

NVR

AM

W1-1

CSU

W1-2

DSX

WAN

IF

T1+

DS1

IAD w/FRS or IPR

CAUTION:

For

con

tinu

ed

prot

ectio

n ag

ainst

fire

,

rep

lace o

nly w

ith t

he sam

e

type and ratin

g of

fuse

Premisy

s Comm

unications

, Inc.

Model IMA

CS/600

T 5A

250V

IEC

Fuse

5A

SB

250V

UL/

CSA

24/48V

5

A

LIS

TED

9K0

9

LR 77

063

120-

200-24

0V

~

3A,

50 /

60 Hz

Teleph

one

Equip

ment

Clas

s 2 P

ower Source

®

®

UL

+ -

+ -

+ -

R
G
R

C
O
M

VN

VB

VA

HSU

-T

530

/35

S

60

HSU-

T

530/35

S

60

HSU-

T

530/3

5

S

60

HSU

-T

530

/35

S

60

HSU-T

530/

35

S

60

HSU

-T

530

/35

S

60

BRI

HSU
530

/35

S

60

P

2

P

1

P

4

P

3

FXO

813

9

N

O

D

E

T

E

R

M

C

O

M

P

P

1

P

1

CPU
CLOCK

NVR

AM

W1-1

CSU

W1-2

DSX

WA

N
IF

T1+

DS1

IAD w/FRS or IPR

SNMP Manager

10 Base-T
Ethernet

Frame Relay

199.190.211.85

199.1.1.2

199.1.1.3

199.1.1.4

199.190.211.113

199.1.1.1

Advertising