5 acs-mcc card error messages, 6 acs-mcc card troubleshooting – Zhone Technologies 600 User Manual

Page 72

Advertising
background image

3-16

Server Cards

Model No.

Running Head

ACS-MCC Card Error Messages

MCC Card

3.5

ACS-MCC Card Error Messages

Refer to Appendix B in the System Reference Guide for further information on Error
Messages regarding this card.

3.6

ACS-MCC Card Troubleshooting

MCC card problems could indicate a number of possible causes, including:

Misconfigured IP parameter at the far end

Faulty cabling between the MCC LAN port and the LAN

T1 or E1 network failure

Improper network configuration

Improper MCC card configuration

Typically, a problem is indicated by the inability to route IP traffic to/from or through the
MCC card. You can perform numerous tasks to isolate the trouble and clear it. When
troubleshooting problems on IP communications through an MCC card, follow this general
sequence:

1. If all IP traffic is affected, verify that the US/EUR jumper is correctly placed to match

the US/EUR jumper on the chassis. The MCC card performs a self-test on power-up.
A “healthy” card will have a green LED lit on the front panel. Do not proceed with
further steps until a green LED is present.

2. Verify that the Ethernet Port (E) is actv and that the correct IP address (IPADDR) and

NETMASK have been entered. At this point, attempt to “ping” (from the CPU card
TCP/IP screen) the IP address of the MCC Ethernet port from another device on the
LAN. Pressing N from this screen will display the Network Statistic registers for the
Ethernet port. Analyze the information to determine the cause of the failure. Do not
proceed with further steps until this ping is successful.

3. From the CPU Main Menu screen, go to the TCP/IP screen by pressing I. Verify that

the options and addresses on the TCP/IP screen are correct. Press “P” (for ping) and
enter the IP address of the MCC card Ethernet port.

4. If Step 3 is not successful, verify that the DEFAULT IP PORT is set to serv and that

the DEFAULT IP SLOT is set to the chassis slot in which the MCC card resides (P1,
P2, or P3). At this point, attempt to ping the card again by pressing P. Do not proceed
until this ping is successful.

5. Verify that the T1 or E1 network is working properly by checking for current CGA-Red

and CGA-Yellow alarms. If no CGA alarms are present that would affect IP traffic,
continue with step 6.