DeviceNet Network Scanner DVPDNET-SL

DVP-PLC Operation Manual

3

1 Introduction

1. To ensure correct installation and operation of DVPDNET-SL, please read this chapter carefully before using

your DVPDNET-SL.

2. This chapter only provides introductory information on DVPDNET-SL. For more detailed information on

DeviceNet protocol, please refer to relevant references or literatures.

3. DVPDNET-SL is a DeviceNet master module operating on the left side of DVP-SV series PLC MPU. When

DVP-SV is connected to DeviceNet through DVPDNET-SL, DVPDNET-SL will serve as the data exchange

interface between DVP-SV and other slaves on the bus. DVPDNET-SL is in charge of sending the data in

DVP-SV to the slaves on the bus, and at the same time collecting the data returned from each slave and

sending them back to DVP-SV.

1.1 Features

z Supports Group 2 server device and Group 2 only server device.

z Supports explicit connection via predefined Master/Slave connection set.

z Supports DeviceNet Master mode and Slave mode.

z Supports EDS configuration in DeviceNet configuration tools.

1.2

Basic Functions of DVPDNET-SL

DVPDNET-SL DeviceNet Network Scanner can be used both as a master or a slave in DeviceNet. When

being used as a master, it supports the following functions:

z Client function of explicit message.

z All kinds of I/O connections established between the slave: polled, bit-strobed, change of state and

cyclic.

z As the connection interface between DeviceNetBuilder configuration software and DeviceNet network.

The configuration software is able to directly configure the network through DVPDNET-SL.

z Sending explicit messages for reading/writing the data in slave through PLC ladder diagrams.

z Automatically exchanging data with PLC MPU. The user needs only to edit the D register in the PLC

without using FROM/TO instruction.

When connected to DVP-SV/DVP-EH2-L MPU,

registers after

D6000 will be adopted temporarily.

z Offering 380-byte space for I/O input data and another 380 bytes for I/O output data.

When being used as a slave, it supports the following functions:

z Explicit message serve and Group 2 only serve connection mode.

z Polling

z Offering 256 bytes for input data and 256 bytes for output data in data exchange with master.

z Automatically exchanging data with PLC MPU. The user needs only to edit the D register in the PLC

without using FROM/TO instruction.