snmp community

Sets two SNMP community strings: read-only and read-write.

To set the community strings for the CoreBuilder 9000, see the
CoreBuilder 9000 Enterprise Management Engine User Guide.

Valid Minimum Abbreviation

sn c

Important Considerations

■

When an SNMP agent receives an SNMP request, the agent compares
the community string in the request with the community strings that
are configured for the agent:

■

SNMP get, get-next, and set requests are valid if the community
string in the request matches the agent’s read-write community.

■

SNMP get and get-next requests are valid if the community string
in the request matches the agent’s read-only community string or
read-write community string.

■

You can specify any string value up to 48 characters long. Do not use
embedded spaces or the # symbol.

■

If you do not want to change the value of a community string, press
Return or Enter at either prompt.

Options

SNMP Community Example (3500)

Select menu option (snmp): community

Enter new read-only community [public]:our_app

Enter new read-write community [private]: my_mail

Prompt

Description

Possible Values

[Default]

Read-only

Octet string, included in each
SNMP message, that provides
read-only access to system
information

■

public

■

A string up to
48 characters
long

public

Read-write

Octet string, included in each
SNMP message, that controls
read-write access to system
information

■

private

■

A string up to
48 characters
long

private