VEGA VEGACOM 557 Siemens 3964 and 3964 R procedure with RK 512 User Manual

Page 13

Advertising
background image

VEGACOM 557 Siemens

13

DIL switch 1 additional board

Selection of the interface

SW 8

SW 7

SW 6

ON

OFF

OFF

RS 232

OFF

ON

OFF

RS 422, RS 485

OFF

OFF

ON

TTY

Bus termination for RS 485, RS 422

SW 5

SW4

ON

ON

bus termination ON

OFF

OFF

bus termination OFF

Selection of the protocol

SW 3

SW 2

SW 1

OFF

OFF

OFF

free

OFF

OFF

ON

free

OFF

ON

OFF

free

OFF

ON

ON

free

ON

OFF

OFF

free

ON

OFF

ON

(ASCII)

ON

ON

OFF

Siemens 3964,
3964 R

ON

ON

ON

(MODBUS RTU/
ASCII)

L R

L R

1

2

1

2

3

Hook switch

= Activation of the TTY interface

= Activation of the RS 232 interface
(factory setting)

Note:
L = position left, R = position right

Top view to the removed additional board

Assignment of the switch positions (hook switch on
additional board)

DIL switch

L R

L R

1

2

L R

L R

1

2

Addressing of the process signals

Additional board bottom view:

Hook switch additional board:

The hook switches enable the selection be-
tween RS 232 and TTY interface

Advertising