3 function, Disbus, Logbus – VEGA VEGACOM 557 Siemens 3964 and 3964 R procedure with RK 512 User Manual

Page 5: Communication process

Advertising
background image

VEGACOM 557 Siemens

5

Product description

DISBUS

LOGBUS

CP524/
CP525

Function VEGACOM 557

Buffer
memory

Proc-
ess
image

Trans-
mis-
sion
memory

Test
conver-
sion

1.3 Function

DISBUS

The new generation of VEGAMET 500 signal
conditioning instruments can transfer meas-
ured data and status information via the
DISBUS to VEGADIS 174 indicating instru-
ments.

VEGACOM 557 receives as participants on
the DISBUS these data in a DCS telegram.
The telegrams are written in VEGACOM 557
into a buffer memory.

LOGBUS

Data are permanently exchanged on the
LOGBUS between the individual components
of VEGALOG 571. VEGACOM 557 receives
as participant of this LOGBUS the part of the
telegrams containing the measured values
and status information.

Communication process

The data communication between VEGACOM
557 and the communication processor
CP 524/525 is only made if initiated by the
PLC which can call up the requested informa-
tion via special commands. The data from
DISBUS/LOGBUS are first written in a buffer
memory in VEGACOM 557.

From this buffer memory, the data set is
transferred into a process image. The protec-
tion converter software enquires the individual
storage section cyclically for the saved val-
ues. The data sets are tested and converted
into the Siemens 3964 or 3964 R data format.
After this conversion, the data are transferred
into the transmission memory and further
transferred to the communication processor.
There, they are read in via a S5 PLC func-
tional component and saved in a data compo-
nent for further processing.

The D-SUB plug in the front plate of
VEGACOM 557 is used for connection of a
PC. In conjunction with the indicating and
adjustment software VEGA Visual Operating
(VVO) configuration and parameter setting of
the VEGAMET signal processing instruments
or the VEGALOG processing system are
possible. In addition measured values and
failure messages can be shown graphically
via the visualisation software Visual VEGA
(VV).

In a planned level, Simatic S5 can additionally
call up beside measured data and status
information also parameters from VEGAMET/
VEGALOG, receive them, if necessary modify
them and return them. This strategy enables
the control of level measurement and process
pressure measuring systems via processing
systems.

Connection VEGACOM 557 on DISBUS

Connection VEGACOM 557 on LOGBUS

DISBUS

LOGBUS

Simatic

S5

CP

524/525

1 ………… 15

VEGAMET

VEGACOM 557
with additional
board S5

Proce-

dure

3964 /R

Instru-

ment

interface

RS 232/RS485/

RS 422/TTY

Simatic

S5

CP

524/525

Procedure

3964 R

Instru-

ment

interface

RS 232/RS485/

RS 422/TTY

VEGACOM 557 with
additional board S5

VEGALOG
571 CPU