VEGA VEGACOM 557 Siemens 3964 and 3964 R procedure with RK 512 User Manual

Page 8

Advertising
background image

8

VEGACOM 557 Siemens

Product description

Indicating elements

LED in front plate
- green "BA"

signal for active communication via
3964/3964 R

- red (flashing)

DISBUS/LOGBUS failure

- red (on)

failure

- green "on"

operating condition

Ambient conditions

Permissible ambient temperature

-20°C … +60°C

Storage and transport temperature

-20°C … +85°C

Moisture

93 %, T = 40°C acc. to DIN/IEC 68-2-3

Shock load

2 … 100 Hz, 0.7 g

Electrical protective measures

Protection:
not mounted

IP 00

in carrier BGT 596
or BGT LOG 571
- front side completely equipped

IP 40

- upper and lower side

BGT 596

IP 00

BGT LOG 571

IP 20

- wiring side

IP 00

in housing type 505
- front side

IP 40

- other sides

IP 30

Protection class

II (in housing type 505)

Overvoltage category

II

Mechanical data

Series

module card for
- carrier BGT 596
- carrier BGT LOG 571
- housing type 505

Dimensions, not mounted

W = 25.4 mm (5 TE), H = 128.4 mm,
D = 166 mm + strap

Weight

approx. 200 g

CE conformity

VEGACOM 557 meets the protective regulations of EMC (89/336/EWG) and NSR
(73/23/EWG). Conformity has been judged acc. to the following standards:
EMC

Emission

EN 50 081 - 1: 1993

Susceptibility

EN 50 082 - 2: 1995

NSR

EN 61 010 - 1: 1993