5 technical data – VEGA VEGACOM 557 Siemens 3964 and 3964 R procedure with RK 512 User Manual

Page 7

Advertising
background image

VEGACOM 557 Siemens

7

1.5 Technical data

Power supply

Operating voltage

U

nom

= 24 V AC (20 … 53 V), 50/60 Hz or
= 24 V DC (20 … 72 V)

Power consumption

approx. 6 VA or approx. 4 W

Fuse

1 A, slow-blow

Galvanic separation

up to 4 kV

Meas. data input DISBUS

Data transmission

DISBUS (digital data transmission)

Connection cable

2-wire unscreened (standard cable)

Cable length

max. 1000 m

Galvanic separation

up to 0.5 kV

Meas. data input LOGBUS

Data transmission

LOGBUS (digital data transmission)

Connection cable

connection via BUS plug

Galvanic separation

up to 0.5 kV

PC interface

Interface standard

RS 232 C

Cable length

max. 15 m (up to 9600 baud)

Connection cable

3-wire, if necessary screened

Transmission rate

300, 600, 1200, 2400, 4800, 9600, 19200 Bit/s

Transmission format

8 data bits, 1 stop bit, even/no parity

Galvanic separation

up to 0.5 kV

Data output to CP 524/CP 525

Interfaces

RS 232

RS 422

RS 485

Cable length

15 m

1200 m

1200 m

Connection cable

3-wire

5-wire

3-wire

twisted in pairs, with braiding and
metal housing plug

Transmission mode

serially asynchronous, half-duplex

Backup

BCC

Coding system

8 bit binary

Number of bits

1 start bit, 8 data bits, 1 parity bit, 1 stop bit

Transmission rate

110, 300; 600; 1200; 2400; 4800; 9600;
19200 baud

Galvanic separation

from the power supply and data input

Electrical connection

Power supply
Meas. data inputs

multiple plug acc. to DIN 41 612, series F,
48-pole, d, b, z

PC interface

D-SUB plug connector, 9-pole pin in
front plate

Product description

Advertising