11

PNEG-1204 Enclosed Belt Conveyors

Conveyor Assembly

INTERMEDIATE SECTION

INSTALLATION (CONT.)

1. Intermediate Sections bolt together along the

side and bottom flanges. The covers are
fastened to the cover channels by flat clips
and easy grip handles.

2. Standard intermediate sections do not have

a direction in which they bolt to other
intermediate sections. The cover channels
connect intermediate sections on both ends.

3. Two inspection intermediate sections are

included on each installation. They should be
assembled at the head and tail. The
inspection holes should be oriented closest
to the head or tail.

4. The inspection door end of each

intermediate section has adapter angles
with slotted holes for bolting to head or
tail sections.

5. A special cover channel is provided with the

tail as shown at right.

Cover Channel

Cover

Easy Grip
Handles

Tail Section

Intermediate
Inspection
Section

Inspection

Door

Tail Cover Channel

Adapter
Angle
with
Slotted
Holes

Flat
Clips

Advertising