Warning – Grain Systems Bucket Elevtors, Conveyors, Series II Sweeps PNEG-1204 User Manual

Page 20

Advertising
background image

15

PNEG-1204 Enclosed Belt Conveyors

Motor Assembly

MOTOR AND TORQUE ARM II

REDUCER INSTALLATION

1. To aid in the installation of the reducer onto

the shaft, remove any protective coating film
from the shaft.

2. Place key in the keyway on the drive shaft.

3. Attach inside bushing to the reducer drive.

4. Line up the keyway on reducer with key on

shaft and slide the reducer drive onto the
drive shaft.

5. Slide outside bushing onto shaft and attach

to reducer drive. Once reducer drive is in
place, fully tighten both bushings.
(See page 38 for more details.)

Reducer

Shaft
Mount
Reducer

Key

Bushing

Conveyor
Drive
Shaft

Shaft
Mount
Reducer

Bushing

Conveyor
Drive Shaft

WARNING

Shear point. Keep hands
clear of moving parts. Do
not operate with guard
removed. Disconnect
and lockout power before
servicing.

DC-995

SHEAR POINT
Keep hands clear of moving
parts. Do not operate with
guard removed. Disconnect
and lockout power before
servicing.

DC-994

DC-994

DC-995

DC-994

DC-995

BELT GUARD
COVER