Vision control panel, Chapter 3 vision control panel, Control power switch stop button – Grain Systems PNEG-1743 User Manual

Page 11: Control power switch, Stop button

Advertising
background image

PNEG-1743 Vision for Tower Dryers

11

3. Vision Control Panel

Figure 3A

Control Power Switch

The Vision control system is turned ON or OFF with this switch.

NOTE: This switch does not disconnect the power that is present at the breakers, contactors, transformer(s),

fuses or other electrical components found in the control or power box. Turn the main disconnect
handle to the OFF position prior to servicing any of the installed components.

Stop Button

This button stops all dryer functions except the blower (fan). If the blower switch, noted on the panel as
the Fan switch, is in the ON position, the blower will continue to run for 15 minutes. If you desire the
blower to be OFF, turn the blower switch to the OFF position. If an automatic dryer shutdown occurs,
first determine and correct the cause of the shutdown. Then, press the Stop button to reset the dryer
before restarting.

Fan switches

Load switch

Unload switch

Outside
Light switch

Control
Power switch

Stop button

Start switch

Meter Roll
Adjustment

Touch screen

Heater switches

Advertising