5. Operations

PNEG-1743 Vision for Tower Dryers

29

7. Data Logger Setup:

By turning the data logger on, it records the following

parameters of the dryer every 5 minutes.

a. Dryer grain temperature

b. Incoming grain temperature

c. Incoming grain moisture

d. Outgoing grain temperature

e. Outgoing grain moisture

f. Meter roll speed

g. Bin number

h. Hour

i. Minute

Figure 5Q

Looking Up Data Logger Records

1. Go to our website (www.grainsystems.com) and click on the “GRAIN DRYER VISION

CONTROL” link at the right side of the page.

2. Download the “LOGVIEWER INSTALLER” at the top right of the page to the desktop.

3. Execute the “LOGVIEWER SETUP” file and install the program.

4. Open the “Dryer Data Logviewer” program.

5. Navigate the menu to “File” -> “Open”. Select the log file that was downloaded

from Vision.

6. Data can be exported to an Excel spreadsheet by “File” -> “Export to spreadsheet file”.